A DPO pelvic osteotomy plate is a veterinary implant used to help maintain a repositioned pelvic or acetabular segment after a planned double pelvic osteotomy in selected canine orthopedic cases. WTT Vet's DPO Plate is available in 20°, 25° and 30° configurations, with right and left versions for each angle. Choosing the correct configuration requires more than selecting a plate by appearance: the angle, laterality, screw construct, instruments and patient-specific surgical plan must be reviewed together.
This guide explains the role of a DPO plate, the available configurations and the main purchasing factors for veterinary hospitals, orthopedic practices and professional distributors.
Double pelvic osteotomy is a rotational pelvic osteotomy technique used in carefully selected canine orthopedic cases involving acetabular repositioning. After the planned pelvic segment has been repositioned, the DPO plate functions as the implant component that helps maintain the planned correction while the osteotomy heals.
The plate is therefore part of a complete surgical system rather than an isolated product. The operating team should review the plate side, plate angle, compatible screws, drilling method, guides and fixation sequence before the procedure. The final implant choice remains the responsibility of the qualified veterinary surgeon and must follow imaging, anatomy, clinical assessment and applicable product documentation.
| Configuration factor | Available options | What to confirm |
|---|---|---|
| Plate angle | 20°, 25° or 30° | Whether the selected angle matches the planned correction and patient assessment |
| Laterality | Right or left | The operative side and the corresponding plate version |
| Fixation | Compatible screw construct | Screw dimensions, quantity, drill size and insertion instruments |
| Procedure support | DPO instruments and drill guides | Availability of the required instruments and documentation |
Plate-angle selection should start with the surgical plan. The veterinary team may consider diagnostic imaging, acetabular orientation, pelvic anatomy, the planned correction and the surgeon's preferred technique. The selected angle must also be available in the correct right or left configuration.
A quotation request should state the exact configuration, such as 20° right, 25° left or 30° right. Clear angle and laterality information helps reduce ordering errors and makes it easier for distributors and hospitals to confirm the correct product before shipment.
DPO plates are side-specific. A right plate and a left plate should not be treated as interchangeable simply because they have the same angle. The operating side, the planned osteotomy and the orientation of the acetabular segment should be confirmed before ordering.
For inventory planning, distributors may record each angle and side as a separate configuration. This is particularly important when a veterinary orthopedic service manages several hospitals or supports procedures with short scheduling windows.
WTT Vet also supplies veterinary surgical power tools, including the A+140 Large Bone Cannulated Drill and the B140 Small Bone Cannulated Drill. These products belong to the broader surgical-tool range and should only be included when their specifications and interfaces match the planned procedure and instruments.
WTT Vet's veterinary implant range includes DPO, TPLO, TTA and advanced locking plate systems. These categories address different orthopedic procedures and should not be substituted for one another based only on the presence of a plate.
For example, the TPLO Plate belongs to the TPLO product line, while the DPO Plate is listed under the DPO System for selected pelvic osteotomy procedures. A procedure-specific implant, compatible instrument set and appropriate fixation components should be confirmed for each case.
WTT Vet supplies veterinary orthopedic implants, instruments and surgical power tools for professional customers. For a DPO Plate quotation, customers should provide the required angle and side, together with any requirements for compatible screws, DPO instruments, drill guides and product documentation.
This information helps the supplier and purchasing team discuss the configuration as a complete system. It also supports clearer communication between veterinary hospitals, distributors and the technical team before shipment.
A DPO pelvic osteotomy plate is a side-specific veterinary implant used to help maintain a repositioned pelvic or acetabular segment after a planned double pelvic osteotomy in selected canine orthopedic cases.
The WTT Vet DPO Plate is available in 20°, 25° and 30° versions, with right and left options for each angle.
The angle should be selected according to diagnostic imaging, patient anatomy, the planned correction and the veterinary surgeon's clinical assessment.
The required angle, right or left side, compatible screws, drill guides, DPO instruments, product documentation and packaging should be confirmed before ordering.
No. The plate should be evaluated together with the compatible screw construct, drill selection, instruments, fixation sequence and patient-specific surgical plan.
Selecting a DPO pelvic osteotomy plate requires a coordinated review of angle, laterality, fixation components and procedure-specific instruments. WTT Vet offers 20°, 25° and 30° right and left configurations for professional veterinary orthopedic customers. By confirming the complete system before ordering, veterinary hospitals and distributors can create a clearer specification for selected canine pelvic osteotomy procedures.
Product information note: This article is provided for product education and purchasing reference. It does not replace veterinary surgical training, clinical judgment, diagnostic imaging, the applicable instructions for use or the regulatory requirements of the relevant market.